Showing posts with label Radiation Basic Training. Show all posts
Showing posts with label Radiation Basic Training. Show all posts

Friday, December 20, 2013

Radioactive Rain Water - What isotopes are in it?





Converting CPM to uSv/hr, Plus Calibration



Converting CPM to uSv/hr, Plus Calibration



You CANNOT use micro sieverts per hour (uSv/hr), MREM/hr, mR/hr, or any other such energy-based unit with a Geiger counter without first knowing the exact energy of the object you are testing. With this knowledge, you can calculate your equivalent dose from exposure, or even calibrate your Geiger counter to do it for you.

NOTE: The math I use was created by me, but is widely used in science, and not new. DO NOT USE the techniques or math I show you for anything you really need to be 100% sure of. This is for fun and there are many additional variables I did not calculate.

USE AT OWN RISK
This is only an approximate means.

The real method for finding the energy of a given isotope is to use a scintillator to measure the energy emitted by the sample. If you REALLY must use a Geiger counter, you might try something like this:

Sv/hr = E(joules) * A(Bq) * 3600s * Wr * H * (100-(r/(ρ cm^3/CSDA cm^2)))/kg Hr
Where:
E = energy per Bq in joules
A = activity in Bq
3600s = 60seconds x 60min
Wr = weighting factor of radiation. Gamma and Beta=1, Alpha=20
H = weighting factor of body part. Use 1 for entire body
/kg Hr = the entire effective energy is divided per kilogram, and per hour.
The last part calculates the change in energy of particle with respect to position within a medium. ρ is the density of air. dE/dx, basically.

Watch the video to see in detail.

Radioactive Units - Do Not Use Them Incorrectly!




Geiger counters count ionizing radiation events.

To measure a detected reading, the energy of the detected radiation must be known. If the detected radiation has an unknown energy, there can be no measure, but merely the detection.

Examples of different energies from common isotopes released by Fukushima (approx):
Cs137 -- 0.5 MeV beta
Cs137 -- 1.1 MeV beta
Cs137 --Ba137m -- 0.6 MeV gamma (often used to calibrate GM's)
Sr90 -- 0.5 MeV beta + weak gamma
I131 -- 333 KeV beta
I131 -- 606 KeV beta
U238 -- 4MeV alpha

As you can see, the energies very quit allot and cannot be assumed.

Here are some energy dependent units:
1 Gray = 1 joule / 1kg
1 Seivert = 1Gy x RadiationFactor x BodyPartFactor
1 RAD = 0.01 joule / 1kg
1 REM = 1 Rad x RadiationFactor
1 Roentgen = = 2.58×10^-4 Coulomb / 1kg

As you can see... each of these units uses a degree of energy. You do not know the energy unless you know the exact nature of your source. As a result, you cannot use them.


In short: If and only if you know the exact energy of your source and a specific calibration and calibrated geometry, you cannot accurately use any energy dependent unit. All such unit measures are meaningless in these cases.

Use Counts Per Minute (CPM) or Counts Per Second (CPS)

Have fun!


Bonus: Links to radiation risk charts:
http://northwestradiology.files.wordpress.com/2011/08/radiation-dosage-chart.png
http://clarkdds.com/blog/wp-content/uploads/2012/08/Radiation-Dose-Chart-copy.jpg